5) Check Ground At Distributor
Measure resistance between ground and GND terminal (Black wire on 2.0L A/T or Black/White wire on 2.5L) at distributor 6-pin connector. If resistance is less than 5 ohms, go to next step. If resistance is 5 ohms or more, repair open GND wire.