Fuel Injector Resistance
Disconnect injector harness connectors. Using digital ohmmeter, measure resistance between injector terminals. If resistance is not 11-19 ohms, replace injector.
NOTE:
For additional testing and information, proceed to FUEL SYSTEM in appropriate SYSTEM/COMPONENT TESTS
article below in this section.
- I - SYSTEM/COMPONENT TESTS - EEC (1.8L) (for Escort & Tracer)
- I - SYSTEM/COMPONENT TESTS - EEC-IV (1.9L) (for Escort & Tracer)
- I - SYSTEM/COMPONENT TESTS - EEC-IV (2.0L) (for Probe)
- I - SYSTEM/COMPONENT TESTS - EEC-IV (2.3L) (for Tempo & Topaz)