Master Switch Test
With ignition off, remove master switch. Leave electrical connector connected. Measure voltage at indicated switch terminals with switch in specified positions. See MASTER SWITCH TESTING table. If voltage is as specified, go to appropriate procedure under TROUBLE SHOOTING if applicable. If voltage is not as specified, replace master switch.
MASTER SWITCH TESTING
| Switch Position | Wire Color | (1) Volts | ||
|---|---|---|---|---|
| Left Up | GRN/BLU | 12 | ||
| Left Up | RED/BLU | 0 | ||
| Left Up | GRN/WHT | 0 | ||
| Left Up | RED/WHT | 0 | ||
| Left Down | GRN/BLU | 0 | ||
| Left Up | RED/BLU | 12 | ||
| Left Up | GRN/WHT | 0 | ||
| Left Up | RED/WHT | 0 | ||
| Left One-Touch | GRN/BLU | 0 | ||
| Left Up | RED/BLU | 12 | ||
| Left Up | GRN/WHT | 0 | ||
| Left Up | RED/WHT | 0 | ||
| Right Up | GRN/BLU | 0 | ||
| Left Up | RED/BLU | 0 | ||
| Left Up | GRN/WHT | 12 | ||
| Left Up | RED/WHT | 0 | ||
| Right Down | GRN/BLU | 0 | ||
| Left Up | RED/BLU | 0 | ||
| Left Up | GRN/WHT | 0 | ||
| Left Up | RED/WHT | 12 | ||
| Right One-Touch | GRN/BLU | 0 | ||
| Left Up | RED/BLU | 0 | ||
| Left Up | GRN/WHT | 0 | ||
| Left Up | RED/WHT | 12 | ||
|
||||