Data Link Diagnostics
- Hook-up New Generation Star (NGS) scan tester. See EQUIPMENT HOOK-UP . Turn ignition switch to RUN position. Highlight and select DATA LINK DIAGNOSTICS, press trigger to start multiplex communication network link test.
- If NGS scan tester display shows CIRCUIT 914 (+) = 0000 and CIRCUIT 915 (-) = 0000, communication network is okay, proceed to ON-DEMAND SELF-TEST or desired testing mode. If NGS scan tester display shows other than CIRCUIT 914 (+) = 0000 and CIRCUIT 915 (-) = 0000, go to next step.
- If NGS scan tester display shows CIRCUIT 914 (+) = 0200 and CIRCUIT 915 (-) = 0200, this indicates all modules except cellular phone module are responding. If vehicle does not have a factory installed cellular phone, communication network is okay, proceed to desired self-testing mode.