Non-Generic OBD-II Parameter Identification (PID)
Turn ignition switch to OFF position. Ensure test equipment is properly attached. Program scan tester using the following steps:
- Select vehicle and engine selection menu. See Figure.
- Select year, engine, model and any additional information requested by scan tester.
- Select GENERIC OBD-II OPTIONS. Press CONT button if monitors are not complete.
- Select DIAGNOSTIC DATA LINK.
- Select PCM - POWERTRAIN CTRL MODULE.
- Select DIAGNOSTIC TEST MODES.
- Select PID DATA MONITOR AND RECORD.
- Turn ignition on or start engine and allow to idle.
- Follow operating instructions from scan tester menu.
- Select PIDs and press START.