Quick Test: Notes
The following procedures are parts of the QUICK TEST. These basic test steps must be followed in sequence to avoid misdiagnosis:
- Perform visual check. See ENTERING SELF-DIAGNOSTICS.
- Perform equipment hookup. See EQUIPMENT HOOKUP.
- KEY ON ENGINE OFF (KOEO) SELF-TEST.
- KEY ON ENGINE RUNNING (KOER) SELF-TEST.
- CONTINUOUS MEMORY SELF-TEST.
- SWITCH MONITOR TEST (If necessary).
- Check Parameter Identification (PID) values.