Diagnostic Command
NOTE:
This procedure may be used to verify operation of the system controlled by the module being tested.
- Connect New Generation Star (NGS) scan tester on Data Link Connector (DLC) and perform proper hook-up procedure. See EQUIPMENT HOOK-UP under COMMUNICATION NETWORK DIAGNOSTICS
.NOTE: Ignition switch must be in ON position or the test will fail.
- Turn ignition switch to ON position unless otherwise instructed by specified test procedure. Rotate dial on scan tester to DIAGNOSTIC DATA LINK menu and press trigger.
- Rotate dial on scan tester to highlight the desired module you wish to access and press trigger. Rotate dial on scan tester to highlight ACTIVE/COMMAND modes and press trigger.
- Rotate dial on scan tester to selected command and press trigger.