Load Test

  1. Ensure drive belt is in good condition and properly tightened. Connect charging system load tester in accordance with manufacturer's instructions. Start and run engine at 2000 RPM and apply load until generator output amperage levels off.
  2. Record maximum generator amperage output. See GENERATOR OUTPUT SPECIFICATIONS table for output values. If generator output is within 20 percent of rated output amperage and voltage remains at 12.5-14.5 volts, generator output is okay. If generator does not produce rated output, proceed with appropriate testing.
GENERATOR OUTPUT SPECIFICATIONS

Application Amps Rating
Contour & Mystique 95