General Procedures: Fill
- Check the fluid level. If necessary, fill the reservoir to the correct level.
- Use Motorcraft MERCON® Multi-Purpose ATF XT-2-QDX or MERCON® equivalent.
- Remove the fuel pump relay from the battery junction box.
- Raise the front wheels off the floor. For additional information, refer to JACKING & LIFTING .
- Turn the steering wheel from stop-to-stop while cranking the engine.
- Lower the vehicle.
- Check the fluid level. If necessary, fill the reservoir to the correct level.
- Use Motorcraft MERCON® Multi-Purpose ATF XT-2-QDX or MERCON® equivalent.
- Install the fuel pump relay in the battery junction box.
WARNING:
Do not mix oil types, any mixture or any unapproved oil could lead to seal deterioration and leaks. A leak could ultimately cause loss of fluid, which could result in a loss of power steering assist.
CAUTION:
Do not crank the engine for more than 15 seconds at a time. Allow the starter to cool for 1 minute before cranking again. Premature starter failure can occur.
CAUTION:
Do not hold the steering wheel against the stops for more than three to five seconds at a time. Damage to the power steering pump could occur.
CAUTION:
Do not overfill the reservoir.