GENERAL SPECIFICATIONS

Item Specification
Normal engine cranking speed 200-250 rpm
Starter motor maximum load current draw 800 amps
Starter circuit maximum voltage drop (engine at normal operating temperature) 0.5 volt
Starter motor no load current draw 60-80 amps
Starter motor normal load current draw 130-190 amps
TORQUE SPECIFICATIONS

Description Nm lb-ft lb-in
Ground wire nut (2.5L) 18 - 159
Ground wire nut (3.0L) 18 - 159
RH splash shield bolts 9 - 80
Starter motor solenoid battery cable nut 12 - 106
Starter motor solenoid wire nut 5 - 44
Starter motor stud bolts (2.5L) 35 26 -
Starter motor stud bolts (3.0L) 27 20 -