Pinpoint Test I : U0155:87
WARNING: This page is about a different car, the 2020 Ford Mustang. However, it is still accessible from the selected car via links, so may be relevant.
- Refer to OEM WIRING DIAGRAMS FOR MODULE COMMUNICATIONS NETWORK
for schematic and connector information.
Normal Operation and Fault Conditions
REFER to: Communications Network - System Operation and Component Description .
DTC Fault Trigger Conditions
DTC Description Fault Trigger Condition BCM U0155:87 Lost Communication With Instrument Panel Cluster (IPC) Control Module: Missing Message A continuous memory DTC that sets in the BCM if messages received from the IPC through the GWM are missing. Possible Sources
- Communication network concern
- Battery voltage concern
- IPC
- BCM
- NOTE: If new modules were installed prior to the DTC being set, the module configuration may be incorrectly set during the PMI or the PMI may not have been carried out.
- I1 CHECK THE COMMUNICATION NETWORK
- Ignition ON.
- Connect the diagnostic tool.
- Using a diagnostic scan tool, perform a network test.
Does the IPC pass the network test?
Yes GO to I2 No REFER to: Communications Network . - I2 CHECK THE BCM (BODY CONTROL MODULE) CONTINUOUS MEMORY DIAGNOSTIC TROUBLE CODES (CMDTCS)
- Using a diagnostic scan tool, clear the Diagnostic Trouble Codes (DTCs).
- Wait 10 seconds.
- Using a diagnostic scan tool, check the BCM CMDTCs.
Is DTC U3006:16, U3006:17, U3007:16, U3007:17, U3013:16, U3013:17, U3014:16 or U3014:17 recorded?
Yes For DTC U3006:16, U3007:16, U3013:16 or U3014:16, GO to Pinpoint Test U For DTC U3006:17, U3007:17, U3013:17 or U3014:17, GO to Pinpoint Test V No GO to I3 - I3 RETRIEVE THE IPC (INSTRUMENT PANEL CLUSTER) MODULE DTCS
- Using a diagnostic scan tool, perform the IPC self-test.
Are any IPC module DTCs present?
Yes REFER to: Instrumentation, Message Center and Warning Chimes . No GO to I4 - I4 RECHECK THE BCM (BODY CONTROL MODULE) CMDTCS
- Using a diagnostic scan tool, clear the DTCs.
- Wait 10 seconds.
- Using a diagnostic scan tool, check the BCM CMDTCs.
Is DTC U0155:87 present?
Yes GO to I5 No The system is operating correctly at this time. The DTC may have been set due to high network traffic or an intermittent fault condition. - I5 CHECK FOR DTC (DIAGNOSTIC TROUBLE CODE) U0155:87 SET IN OTHER MODULES
- Using a diagnostic scan tool, clear the DTCs.
- Ignition OFF.
- Ignition ON.
- Wait 10 seconds.
- Using a diagnostic scan tool, retrieve all CMDTCs.
Is DTC U0155:87 set in other modules?
Yes GO to I6 No GO to I7 - I6 CHECK FOR CORRECT IPC (INSTRUMENT PANEL CLUSTER) OPERATION
- Disconnect and inspect all IPC connectors.
- Repair:
- corrosion (install new connector or terminals - clean module pins)
- damaged or bent pins - install new terminals/pins
- pushed-out pins - install new pins as necessary
- Reconnect all IPC connectors. Make sure it seats and latches correctly.
- Operate the system and determine if the concern is still present.
Is the concern still present?
Yes CHECK OASIS for any applicable service articles: TSB, GSB, SSM or FSA. If a service article exists for this concern, DISCONTINUE this test and FOLLOW the service article instructions. If no service articles address this concern, Refer to IPC Guided Routine Testing . No The system is operating correctly at this time. The concern may have been caused by module connections. ADDRESS the root cause of any connector or pin issues. - I7 CHECK FOR CORRECT BCM (BODY CONTROL MODULE) OPERATION
- Disconnect and inspect all BCM connectors.
- Repair:
- corrosion (install new connector or terminals - clean module pins)
- damaged or bent pins - install new terminals/pins
- pushed-out pins - install new pins as necessary
- Reconnect all BCM connectors. Make sure they seat and latch correctly.
- Operate the system and determine if the concern is still present.
Is the concern still present?
Yes CHECK OASIS for any applicable service articles: TSB, GSB, SSM or FSA. If a service article exists for this concern, DISCONTINUE this test and FOLLOW the service article instructions. If no service articles address this concern, Refer to BCM Guided Routine . No The system is operating correctly at this time. The concern may have been caused by module connections. ADDRESS the root cause of any connector or pin issues.