LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Ford >> 2020 >> Explorer ST >> Repair and Diagnosis >> Engine Performance >> System >> Engine Controls - Reference Values (Except Diesel & Hybrid) >> 2.0L ECOSPORT >> Typical Diagnostic Reference Values
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Typical Diagnostic Reference Values

Inputs Component/PID Only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
AAT AAT Sensor -3 (26.6) -3 (26.6) -3 (26.6) -8 (17.6) DEG C (DEG F)
AAT_V AAT Sensor 2.81 2.92 4 4.24 VOLTS
AC_ REQ PID NO NO NO NO YES/NO
APP APP Sensor 0 0 18 0 %
APP1 APP Sensor 0.77 0.77 1.34 0.77 VOLTS
APP1 (APP_D) APP Sensor 15 15 27 15 %
APP2 APP Sensor 0.39 0.39 0.67 0.39 VOLTS
APP2 (APP_E) APP Sensor 7 7 13 7 %
APP_ MAXDIFF PID 0 0 0 0 DEG
APP_ MODE PID NO PEDAL NO PEDAL PART PEDAL PART PEDAL NO PEDAL/PART PEDAL
BARO PID 100 (14.50) 100 (14.50) 100 (14.50) 100 (14.50) kPa (PSI)/
BARO_V PID 3.98 3.98 3.98 3.98 VOLTS
BOO1 BPP Switch FALSE FALSE FALSE FALSE TRUE/FALSE
BOO2 BPP Switch FALSE FALSE FALSE FALSE TRUE/FALSE
BRKOVRD_ POSS PID 1 1 2 2 NUMERIC VALUE
BRKOVR_ ACTION PID 0 0 0 0 NUMERIC VALUE
CATEMP11 CAT11 Sensor 521 (969.8) 535 (995) 682 (1259.6) 852 (1565.6) DEG C (DEG F)
CHT CHT Sensor 96 (204.8) 94 (201.2) 93 (199.4) 92 (197.6) DEG C (DEG F)
CHT_V CHT Sensor 3.47 3.52 3.56 3.58 VOLTS
CLRDIST PID 0 0 0 2 (1.24) KM (MILES)
DECHOKE PID YES NO NO NO YES/NO
DTCCNT PID 1 1 1 1 NUMERIC VALUE
ECT ECT Sensor 90 (194) 92 (197.6) 93 (199.4) 88 (190.4) VOLTS/DEG C (DEG F)
ECT1_V ECT Sensor 0.60 0.57 0.59 0.58 VOLTS
EQ_RAT11 PID 0 1.02 0.99 0.98 RATIO
ETC_ACT PID 8.85 1.14 5.20 21.10 DEG
ETC_TRIM PID -0.01 -0.01 -0.02 -0.02 DEG
FLI Fuel Level Sensor 60 (H) 60 (H) 49 (H) 49 (H) %
FLP Fuel Pressure Sensor 509 (73.82) 584 (84.70) 549 (79.63) 549 (79.63) kPa (PSI)
FLP_V Fuel Pressure Sensor 3.95 3.80 3.59 3.59 VOLTS
FPM PID 39 40 40 40 %
FRP FRP Sensor 4570 (662.82) 2080 (301.68) 10020 (1453.28) 10020 (1453.28) kPa (PSI)
FRP_V FRP Sensor 1.28 0.85 2.20 2.20 VOLTS
FTP_V FTP Sensor 2.64 2.66 1.86 1.86 VOLTS
HTRCM11 HO2S11 Sensor 0 0 1.40 1.50 A
HTRCM12 HO2S12 Sensor 0 0 1.40 1.50 A
IAT IAT Sensor 25 (77) 13 (55.4) 3 (37.4) 3 (37.4) DEG C (DEG F)
IAT1_V IAT Sensor 2.40 3.02 3.49 3.49 VOLTS
INJPWR_M PID 0 0 0 0 VOLTS
KNOCK_1 KS1 Sensor 167 75 78 173 COUNT
KNOCK_2 KS2 Sensor 167 84 107 209 COUNT
LOAD PID 0.00 (I) 27 39 95 %
LONGFT1 PID (I) -20 TO +20 -20 TO +20 -20 TO +20 %
MAF MAF Sensor 0 3.18 10.20 35.24 g/s
MAF_HZ MAF Sensor 0.71 1.74 2.89 4.70 kHz
MIL_DIS PID 0 0 0 0 KM (MILES)
MISFIRE PID FALSE FALSE FALSE FALSE TRUE/FALSE
MP_LRN PID YES YES YES YES YES/NO
NUM_ MISFIRE PID 0 0 0 0 COUNT
O2S11_CUR HO2S11 Sensor (I) switching switching switching mA/uA
O2S11_ IMPED HO2S11 Sensor 4.93 4.21 1.03 1.02 VOLTS
O2S11_ READY HO2S11 Sensor FALSE FALSE TRUE TRUE TRUE/FALSE
O2S11_TR HO2S11 Sensor 0 0 0 0 Kohm
O2S12 HO2S12 Sensor (I) switching (D) switching (D) switching (D) VOLTS
OCTADJ_R_ LRND PID 0 0 0 0 %
OSS_SRC OSS Sensor 0 0 1311 2620 RPM
RO2FT1 PID 0 0 0.01 0.01 %
RPM CKP Sensor 0 822 1954 2239 RPM
SHRTFT1 PID (I) -10 TO +10 -10 TO +10 -10 TO +10 %
SYNC PID NO YES YES YES YES/NO
TP1_PER ETBTPS 17 10 12 23 %
TP1_V ETBTPS 4.14 4.47 4.38 3.82 VOLTS
TP2_PER ETBTPS 17 11 12 24 %
TP2_V ETBTPS 0.87 0.53 0.63 1.18 VOLTS
TP_MAXDIFF PID 0 0 0 0 %
TP_REL PID 8 2 4 15 VOLTS
TQ_CNTRL PID ANTI THEFT IDLE SPEED CONTROL NONE REQUESTED CRUISE CONTROL STATUS
VCTSYS PID OPEN LOOP CLOSED LOOP CLOSED LOOP CLOSED LOOP OPEN LOOP/CLOSED LOOP
VCT_EXH_ ACT1 PID 0 -0.38 23.88 17 DEG
VCT_EXH_ DIF1 PID 0 0.38 -0.13 0 DEG
VCT_INT_ ACT1 PID 0 -9.63 -0.50 -32.94 DEG
VCT_INT_ DIF1 PID 0 -0.19 0.50 -0.06 DEG
VSS PID 0 0 48 km/h (30 MPH) 89 km/h (55 MPH) km/h/MPH
Outputs Component/PID Only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
AEIS ACTION PID 1 1 1 1 NUMERIC VALUE
AEIS_ POSS PID 16 16 16 16 NUMERIC VALUE
DIST_ AEIS PID 1 (0.62) 1 (0.62) 1 (0.62) 2 (1.24) KM (MILES)
ETC [TAC_PCT] PID 8 1 6 25 %
EVAP020C PID NO NO NO NO YES/NO
EVAPCP EVAPCP Valve 0 0 12 96 %
EVAPCV CANV Valve 0 0 0 0 %
EVAPPCT PID 0 0 11 96 %
EVAPSOAK PID NO NO NO NO YES/NO
EVAPSTA PID NOT RUNNING NOT RUNNING NOT RUNNING NOT RUNNING STATUS
EVBV EVAP Vapor Blocking Valve 0 0 100 100 %
FP Fuel Pump Control Module 75 26 30 30 %
FRP_DSD PID 370 (53.66) 1990 (288.63) 9900 (1435.87) 9900 (1435.87) kPa (PSI)
FUELSYS_CL PID OPEN LOOP CLOSED LOOP CLOSED LOOP CLOSED LOOP OPEN LOOP/CLOSED LOOP
FUELSYS_OL PID OPEN LOOP CLOSED LOOP CLOSED LOOP CLOSED LOOP OPEN LOOP/CLOSED LOOP
F_VCV Fuel Injection Pump 0 1 21 21 %
HFC PID OFF OFF OFF OFF ON/OFF
HTR11 HO2S11 Sensor OFF ON ON ON ON/OFF
HTR12 HO2S12 Sensor OFF ON ON ON ON/OFF
INJECTOR_ OFF Injector 1-4 -- -- -- -- --DISABLE
LFC PID OFF OFF OFF OFF ON/OFF
MIL PID OFF OFF OFF OFF ON/OFF
O2S11_HTR HO2S11 Sensor 0 87 40 37 %
O2_DS_DISBL PID YES NO NO NO YES/NO
PATSENABL PID ENABLED ENABLED ENABLED ENABLED ENABLED/DISABLED
RPMDSD PID 900 856 856 800 RPM
SPARKADV PID 0 16.50 44.50 16 DEG
VCT_EXH_DC1 VCT12 Solenoid 0 0 48 45 %
VCT_INT_DC1 VCT11 Solenoid 0 32 0 40 %
Other Component/PID Only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
VPWR PID VBAT VBAT VBAT VBAT VOLTS
VREF PID 5 5 5 5 VOLTS