General Specifications

Item Specification
2.3L EcoBoost - Limited and XLT with trailer tow vehicles built before October 2020 
Rating 220 amps
Generator amps at 80.6°F (27°C) 117.9 amps at 700 rpm (min) to 231.1 amps at 2, 500 rpm (max)
Generator pulley ratio 2.44
Generator pulley replaceable Yes
Generator pulley type Overrunning Alternator Decoupler (OAD)
Voltage regulator type Electronic internal with generator
2.3L EcoBoost - Base, XLT and Timberline vehicles built after October 2020 
Rating 150 amps
Generator amps at 80.6°F (27°C) 94.7 amps at 750 rpm (min) to 134.7 amps at 2, 500 rpm (max)
Generator pulley ratio 2.76
Generator pulley replaceable Yes
Generator pulley type Overrunning Alternator Decoupler (OAD)
Voltage regulator type Electronic internal with generator
2.3L EcoBoost - Limited vehicles built after June 2021 
Rating 200 amps
Generator amps at 80.6°F (27°C) 108.5 amps at 700 rpm (min) to 219.3 amps at 2, 500 rpm (max)
Generator pulley ratio 2.44
Generator pulley replaceable Yes
Generator pulley type Overrunning Alternator Decoupler (OAD)
Voltage regulator type Electronic internal with generator
3.0L EcoBoost - All except police vehicles built before October 2020 
Rating 220 amps
Generator amps at 80.6°F (27°C) 112.6 amps at 625 rpm (min) to 233.7 amps at 2, 500 rpm (max)
Generator pulley ratio 2.69
Generator pulley replaceable Yes
Generator pulley type Overrunning Alternator Decoupler (OAD)
Voltage regulator type Electronic internal with generator
3.0L EcoBoost - All ST vehicles built after October 2020 
Rating 220 amps
Generator amps at 80.6°F (27°C) 112.6 amps at 625 rpm (min) to 233.7 amps at 2, 500 rpm (max)
Generator pulley ratio 2.69
Generator pulley replaceable Yes
Generator pulley type Overrunning Alternator Decoupler (OAD)
Voltage regulator type Electronic internal with generator
3.0L EcoBoost - King Ranch. Platinum vehicles built after June 2021 
Rating 200 amps
Generator amps at 80.6°F (27°C) 95.1 amps at 625 rpm (min) to 184 amps at 2, 500 rpm (max)
Generator pulley ratio 2.69
Generator pulley replaceable Yes
Generator pulley type Overrunning Alternator Decoupler (OAD)
Voltage regulator type Electronic internal with generator
3.0L EcoBoost - Police vehicles 
Rating 250 amps
Generator amps at 80.6°F (27°C) 103.3 amps at 625 rpm (min) to 226.5 amps at 2, 500 rpm (max)
Generator pulley ratio 2.69
Generator pulley replaceable Yes
Generator pulley type Overrunning Alternator Decoupler (OAD)
Voltage regulator type Electronic internal with generator
3.3L Duratec - All except police vehicles 
Rating 200 amps
Generator amps at 80.6°F (27°C) 95.1 amps at 625 rpm (min) to 184 amps at 2, 500 rpm (max)
Generator pulley ratio 2.67
Generator pulley replaceable Yes
Generator pulley type Overrunning Alternator Decoupler (OAD)
Voltage regulator type Electronic internal with generator
3.3L Duratec - Police vehicles 
Rating 250 amps
Generator amps at 80.6°F (27°C) 106.5 amps at 625 rpm (min) to 199 amps at 2, 500 rpm (max)
Generator pulley ratio 2.67
Generator pulley replaceable Yes
Generator pulley type Overrunning Alternator Decoupler (OAD)
Voltage regulator type Electronic internal with generator