Item Specification
1.5L EcoBlue 
Generator amps at 80.6deg.F (27deg.C) 130 amps at 675 rpm (min) to 240 amps at 2, 250 rpm (max)
Generator pulley ratio 2.69:1
Generator pulley replaceable Yes
Generator pulley type Overrunning Alternator Decoupler (OAD)
Voltage regulator type Electronic internal with generator
2.0L Duratec 
Generator amps at 80.6deg.F (27deg.C) 130 amps at 675 rpm (min) to 200 amps at 2, 250 rpm (max)
Generator pulley ratio 2.78:1
Generator pulley replaceable Yes
Generator pulley type Overrunning Alternator Decoupler (OAD)
Voltage regulator type Electronic internal with generator
2.5L Duratec 
Generator amps at 80.6deg.F (27deg.C) 130 amps at 640 rpm (min) to 200 amps at 2, 250 rpm (max)
Generator pulley ratio 2.76:1
Generator pulley replaceable Yes
Generator pulley type Overrunning Alternator Decoupler (OAD)
Voltage regulator type Electronic internal with generator