Time Delay Relay

Remove temperature switch wire at temperature switch. Turn ignition switch on. Solenoid should energize for 20-25 seconds and then de-energize. If it does not de-energize, remove purple lead from delay relay. Solenoid will de-energize, delay relay is faulty.