Code 42 - Ignition Control: Notes
Code 42 indicates ECM has seen an open or short to ground in the Ignition Control (IC) or by-pass circuits.
NOTE:
Test numbers refer to test numbers on diagnostic chart.
- This test confirms Code 42 and determines if fault is a hard failure or intermittent condition.
- This tests for a normal IC ground path through ignition module. If circuit is shorted to ground, reading will be less than 500 ohms.
- As test light voltage touches by-pass circuit, module should switch. This causes ohmmeter to "over-range" with meter in 100-200 ohm range. A higher ohm range will indicate over 5000 ohms. This test assures module switched.
- If module did not switch, this step tests for a short in IC circuit, an open in by-pass circuit and a faulty ignition module connection or module.
- This step confirms Code 42 is a faulty ECM and not an intermittent problem in IC and by-pass circuits.