Intermittent Simulation
Use the following methods to reproduce conditions causing intermittent.
- Apply light vibration to components.
- Heat component.
- Wiggle or bend wiring harness.
- Spray component with water.
- Remove/apply vacuum supply source.
Monitor circuit/component voltage or resistance while attempting to simulate intermittent. If vehicle is running, monitor for trouble codes. Use test results to identify faulty component or circuit.