Off-Board Programming (Corvette)
NOTE:
DO NOT program a control module unless you are directed by a service procedure or you are directed by a technical service bulletin. Programming a control module at any other time will not permanently correct a customer's concern.
NOTE:
DO NOT disturb the tool harnesses while programming. If an interruption occurs during the programming procedure, programming failure or control module damage may occur.
Before Programming a Control Module
- Ensure that all connections are secure at the following locations:
- The Off-Board Programming Adapter.
- The Tech 2™.
- The control module.
- The Techline™ terminal.
The Off-Board Programming is used in situations where a control module must be programmed without having the vehicle present. The Off-Board Programming Adapter must be used to perform the Off-Board Programming procedure. The adapter allows the control module to power up and allows the Tech 2™ to communicate with the control module.
Off-Board Programming Procedure
- Obtain the VIN of the vehicle for which the control module is being programmed.
- With the Techline™ terminal, select Service Programming.
- Select Tech 2™, Reprogram ECU, and Off-Board Programming Adapter as the ECU location.
- Connect the control module, Off-Board Programming Adapter, and the Tech 2™ as described on the Techline™ terminal. Ensure you use the correct harness connector from the Off-Board Programming Adapter kit.
- With the Tech 2™, select Service Programming Request Information function. The Tech 2™ communicates with the control module and receives the access code.
- With the Tech 2™, exit the Service Programming Request Information.
- Disconnect the Tech 2™ from the Off-Board Programming Adapter.
- Connect the Tech 2™ to the Techline™ terminal.
- Turn ON the Tech 2™.
- With the Techline™ terminal, enter the VIN of the vehicle that will be receiving the control module.
- The Techline™ terminal will display the message, attaching to database.
- Identify what type of programming that you are performing.
- Select the appropriate calibration file.
- Ensure all connections are secure.
- The Techline™ terminal displays a summary screen that summarizes your selections. After confirming you choices, the Techline™ terminal automatically loads the calibration files to the Tech 2™.
- After the download is complete, turn OFF the Tech 2™.
- Disconnect the Tech 2™ from the Techline™ terminal.
- Connect the Tech 2™ to the Off-Board Programming Adapter.
- With the Tech 2™, select Service Programming.
- With the Tech 2™, select Program.
- After the download is complete, exit Service Programming.
- Turn OFF the Off-Board Programming Adapter.
NOTE:
DO NOT turn OFF the Off-Board Programming Adapter if the programming procedure is interrupted or unsuccessful. Ensure the control module and the Off-Board Programming Adapter connections are secure and the Techline™ operating software is up to date. Attempt to reprogram the control module. If the control module cannot be programmed, replace the control module. See appropriate REMOVAL, OVERHAUL & INSTALLATION article.