Installation Procedure
- Install the air cleaner housing by pressing downward on the housing until the grommets are seated on the mounting studs.
- Install the air cleaner housing mounting nut.
Tighten: Tighten the nut to 10 N.m (89 lb in).
- Insert the MAF sensor into the air cleaner housing cover.
- Secure the air cleaner housing to the MAF sensor.
Tighten: Tighten the MAF sensor clamp to 4 N.m (35 lb in).
NOTE:
Refer to Fastener Notice in Cautions and Notices.
NOTE:
Refer to Mass Air Flow (MAF) Handling Notice in Cautions and Notices.