Installation Procedure
IMPORTANT:
DO NOT use the old cap, CMP sensor, and rotor screws. Use the replacement screws that have been coated with a thread locking compound.
- Insert the CMP sensor through the reluctor wheel slot.
- Install new CMP mounting screws.
Tighten: Tighten the bolts to 2.2 N.m (19 lb in).
- Install the rotor onto the reluctor wheel.
- Install new rotor screws.
Tighten: Tighten the screws to 2 N.m (18 lb in).
- Install the distributor cap.
- Install new distributor cap screws.
Tighten: Tighten the screws to 2.4 N.m (21 lb in).
- Connect the CMP sensor harness connector.
- Connect the spark plug wires and ignition coil wire. Refer to Spark Plug Wire Replacement .
NOTE:
Refer to Fastener Notice in Cautions and Notices.