The brake pressure sensor calibration can be completed with a scan tool using the following steps:

  1. Place the vehicle on a flat level surface.
  2. Apply the parking brake, or set the transmission in the Park.
  3. Release the brake pedal.
  4. Install the scan tool to the data link connector.
  5. Engine running
  6. Select Brake Pressure Sensor Calibration in the Brake System Control Module Configuration/Reset Functions list.
  7. Follow the scan tool directions to complete the calibration learn procedure.
  8. Clear any DTCs that may be set.