Component Testing
Liftgate Unlatch Switch
- Ignition OFF, disconnect the harness connector at the S46B Liftgate Unlatch Switch.
- Test for infinite resistance between the signal terminal 1 and the low reference terminal 2 with the switch in the open position.
- If less than infinite resistance
Replace the S46B Liftgate Unlatch Switch.
- Go to next step: If infinite resistance
- If less than infinite resistance
- Test for less than 3 Ω between the signal terminal 1 and the low reference terminal 2 with the switch in the closed position.
- If 3 Ω or greater
Replace the S46B Liftgate Unlatch Switch.
- Go to next step: If less than 3 Ω
- If 3 Ω or greater
- All OK
Liftgate Close Switch
- Ignition OFF, disconnect the harness connector at the B70 Liftgate Close Switch.
- Test for infinite resistance between the signal terminal 4 and the low reference terminal 3 with the switch in the open position.
- If less than infinite resistance
Replace the B70 Liftgate Close Switch.
- Go to next step: If infinite resistance
- If less than infinite resistance
- Test for less than 3 Ω between the signal terminal 4 and the low reference terminal 3 with the switch in the closed position.
- If 3 Ω or greater
Replace the B70 Liftgate Close Switch.
- Go to next step: If less than 3 Ω
- If 3 Ω or greater
- All OK
Interior Liftgate Control Switch
- Ignition OFF, disconnect the harness connector at the S45B Liftgate Control Switch-Interior.
- Test for infinite resistance between the signal terminal 4 and the ground terminal 2 with the switch in the open position.
- If less than infinite resistance
Replace the S45B Liftgate Control Switch-Interior.
- Go to next step: If infinite resistance
- If less than infinite resistance
- Test for less than 3 Ω between the signal terminal 4 and the ground terminal 2 with the switch in the closed position.
- If 3 Ω or greater
Replace the S45B Liftgate Control Switch-Interior.
- Go to next step: If less than 3 Ω
- If 3 Ω or greater
- All OK