Diagnosis And Testing - Power Trunk Lid System

The power trunk lid system is a complex system containing many components. In order to perform accurate testing, or receive outputs the power trunk lid control module must be checked.

The most reliable, efficient, and accurate means to diagnose the power trunk lid system requires the use of a scan tool and the proper Body Diagnostic Procedures (refer to POWER TRUNK MODULE DIAGNOSIS ). The scan tool can be used to observe current switch status recorded in the power trunk lid control module to help the technician diagnose an inoperative switch.

Before any testing of the power trunk lid system is attempted, the battery shall be fully charged, and the module shall recognize all limiting conditions of the system (Refer to power trunk lid system description for list, refer to Operation ).

Following is a diagnostic table for quick reference to help when diagnosing and testing the power trunk lid system.

No Item Specification description Output
Form
1 A_VBAT Bat Voltage on PTM Voltage (V)
2 Hall SNSR power voltage Hall sensor voltage PTM input
3 LED ON/OFF Vbatt Power (between 9.0v and 16v) ON/OFF
4 Trunk Lid Latch SW Trunk main Switch
5 P_Striker_SW Trunk Lid outside Handle switch
6 Trunk_Trim_Close SW Trunk Inner Push Button
7 Trunk_INR_Push Button Trunk Trim Close
8 Trunk Lid O/S HDL SW Power Striker Switch
9 Trunk main SW Trunk Lid Latch Switch
10 Vbatt Power Voltage in Range LED On/Off
11 Drive Motor Operating Voltage Drive motor Open/Close voltage PTM output Voltage (V)
12 Power Striker Operating Voltage Power Striker motor Pop-up/Close Voltage PTM output
13 Trunk Lid Position Current Trunk position in counter %
14 Unknown Trunk Lid Position Flag Learn Process Complete Status ON/OFF
15 Learn Process Complete Status Unknown Trunk Lid Position Flag ON/OFF
16 Most recent close time (P/Striker) Most recent close time ms
17 2ND Most recent close Time (P/Striker) 2ND Most recent close time