Repair Procedures: Inspection
- Turn the ignition switch OFF.
- Disconnector canister close valve connector.
- Measure resistance between the canister close valve terminals 1 and 2.
- Check that the resistance is within the specification.
Specification: 23.0 - 26.0 [20°C (68°F)]
- Disconnect the vapor hose connected with the canister from the CCV.
- Connect a vacuum pump to the nipple.
- Apply vacuum to the valve with the battery power (B +) applied.
Specification: Vacuum maintained