Retrieving Codes
- Ensure battery has a minimum of 11 volts. Always use a digital type test meter. Never connect or disconnect ECM wiring harness connector when ignition switch is in the "ON" position.
- When performing diagnostic procedures, DO NOT apply meter probes to ECM unless wiring harness connector is attached. Checks are made from the rear side of the ECM wiring harness connector.
- When performing terminal checks, ensure that negative probe is grounded to vehicle body. Before checking for trouble codes, perform diagnostic circuit check. This will ensure on-vehicle diagnostics is working. Refer to DIAGNOSTIC CIRCUIT CHECK chart.
- Insert spare fuse into "Diagnosis Switch Terminal", located in passenger compartment fuse block. Proceed to CODE CHARTS for diagnosing stored codes.