AIR TEMPERATURE SENSOR RESISTANCE (METRO & TRACKER) (1)

Temperature °F (°C) Resistance Ohms
68 (20) 2210-2690
104 (40) 1140
140 (60) 580
176 (80) 290-350
(1) Measure resistance between terminals.
AIR VALVE COOLANT TEMPERATURE SENSOR (METRO)

Temperature °F (°C) Valve Position
140 (60) Fully Closed
CTS RESISTANCE (METRO, SPECTRUM & TRACKER) (1)

Temperature °F (°C) Resistance Ohms
Metro
68 (20) 2210-2690
104 (40) 1140
140 (60) 580
176 (80) 290-350
Spectrum
68 (20) 2100-2900
Tracker
68 (20) 2280-2870
104 (40) 1060
140 (60) 530-700
176 (80) 290-390
(1) Measure resistance between terminals.
MAT SENSOR RESISTANCE (METRO & TRACKER) (1)

Temperature °F (°C) Resistance Ohms
210 (99) 185
160 (71) 450
100 (38) 1800
70 (21) 3400
40 (4) 7500
20 (-7) 13,500
0 (-18) 25,000
-40 (-40) 100,000
(1) Measure resistance between terminals.
OXYGEN SENSOR VOLTAGE

Condition Volt
Lean .1
Rich .9
THROTTLE POSITION SENSOR RESISTANCE (METRO A/T)

Position Resistance Ohms
Idle (1) 4370-8130
Idle (2) 240-1140
WOT (2) 3170-6600
(1) Measure resistance between terminals "A" and "D".
(2) Measure resistance between terminals "A" and "C".
Fig 1: Throttle Position Sensor/Idle Switch Terminal Identification (Metro A/T)
G121733Courtesy of GENERAL MOTORS CORP.