Engine Controls - Sensor Operating Range Charts: Introduction: Notes
Sensor operating range information can help determine if a sensor is out of calibration. An out-of-calibration sensor may not set a trouble code, but it may cause driveability problems.
NOTE:
Unless stated otherwise in test procedure, perform all voltage tests using a Digital Volt-Ohmmeter (DVOM) with a minimum 10-megohm input impedance.
COOLANT TEMPERATURE SENSOR RESISTANCE
| Temperature °F (°C) |
Ohms |
| Prizm & Prizm GSi |
|
EGR TEMPERATURE SENSOR RESISTANCE
| Temperature °F (°C) |
Ohms |
| 112 (50) |
69,000-80,000 |
| 212 (100) |
11,000-15,000 |
| 302 (150) |
2000-4000 |
IAT SENSOR RESISTANCE
| Temperature °F (°C) |
Ohms |
| Prizm & Prizm GSi |
|
KNOCK SENSOR RESISTANCE
| Application |
Ohms |
| Prizm GSi |
3300-4500 |
OXYGEN SENSOR HEATER RESISTANCE
| Application |
Ohms |
| Prizm GSi |
3.5-14 |
THROTTLE POSITION SENSOR (TPS) RESISTANCE (GSi)
| Condition |
Resistance (Ohms) |
| Between Terminals E2 & IDL |
Continuity |
| Between Terminals E2 & IDL |
No Continuity |