Engine Controls - Sensor Operating Range Charts: Introduction: Notes
Sensor operating range information can help determine if a sensor is out of calibration. An out-of-calibration sensor may not set a trouble code, but it may cause driveability problems.
NOTE:
Unless stated otherwise in test procedure, perform all voltage tests using a Digital Volt-Ohmmeter (DVOM) with a minimum 10-megohm input impedance.
COOLANT TEMPERATURE SENSOR RESISTANCE
| Temperature °F (°C) | Ohms |
|---|---|
| -40 (-40) | 100,700 |
| 0 (-18) | 25,000 |
| 20 (-7) | 13,500 |
| 40 (4) | 7500 |
| 70 (21) | 3400 |
| 100 (38) | 1800 |
| 160 (71) | 450 |
| 210 (99) | 185 |
EGR TEMPERATURE SENSOR RESISTANCE
| Temperature °F (°C) | Ohms |
|---|---|
| -4 (-20) | 69,000 |
| 32 (0) | 28,000 |
| 68 (20) | 12,100 |
| 104 (40) | 5800 |
| 140 (60) | 3060 |
| 176 (80) | 1700 |
| 212 (100) | 1000 |
| 248 (120) | 620 |
| 284 (140) | 400 |
| 320 (160) | 270 |
| 356 (180) | 190 |
| 392 (200) | 135 |
| 428 (220) | 100 |
| 464 (240) | 74 |
| 500 (260) | 58 |
| 536 (280) | 45 |
| 572 (300) | 36 |
IAT SENSOR RESISTANCE
| Temperature °F (°C) | Ohms |
|---|---|
| -40 (-40) | 100,700 |
| 0 (-18) | 25,000 |
| 20 (-7) | 13,500 |
| 40 (4) | 7500 |
| 70 (20) | 3400 |
| 100 (38) | 1800 |
| 160 (71) | 450 |
| 210 (99) | 185 |
OXYGEN SENSOR HEATER RESISTANCE
| Application | Ohms |
|---|---|
| Storm GSi | 3.5-14 |
THROTTLE POSITION SENSOR (TPS) RESISTANCE
| Application | Resistance (Ohms) | ||
|---|---|---|---|
| Storm GSi | (1) | ||
|
|||