Solenoid Pull-In Coil Test
NOTE:
The following solenoid tests must be performed with starter
assembled and field lead disconnected from starter at
solenoid.
CAUTION:
DO NOT
engage
starter solenoid for longer than 5 seconds
during testing or damage to coil winding may result.
- Disconnect field lead from solenoid field lead terminal. See Fig 1. Ensure field lead does not touch starter housing. Connect negative lead of 12-volt battery to solenoid field lead terminal (terminal "C").
- Connect another negative battery lead to starter drive housing. Connect positive battery lead to solenoid ST terminal. See Fig 1.
- Pinion gear should extend quickly and completely when solenoid is energized. If pinion gear does not operate as indicated, replace solenoid.