IGNITOR (Power Unit)
- Disconnect distributor harness connector. Connect two 1.5 volt batteries together in series (3 volts). Using an ohmmeter, connect positive lead to terminal No. 4 of distributor and negative lead to terminal No. 6. See Fig 1
.
- Check continuity between terminals No. 4 and 6 as positive side of batteries is connected to terminal No. 5 of distributor and negative side is connected to terminal No 4. See Fig 1
. Continuity should only exist with voltage applied to terminal No. 5. Replace distributor if continuity is not as specified.
Courtesy of SUZUKI OF AMERICA CORP. IGNITOR RESISTANCE
| Positive Lead |
Negative Lead |
Continuity |
| "E" |
"I" |
Yes |
| "E" |
"G" |
Yes |
| "I" |
"G" |
Yes |
| "I" |
"E" |
No |
| "G" |
"E" |
No |
| "G" |
"I" |
Yes |