Vacuum Switch A
- Disconnect vacuum hose No. 2 to control box at vacuum hose manifold. Connect hand vacuum pump to hose. Check for continuity between Black/Yellow and Brown/White terminals of control box connector.
- Apply more than 4 in. Hg. Continuity should not be present. If continuity is present, replace vacuum switch A. Release vacuum. Continuity should be present. If not, replace vacuum switch A.