Civic 1500 (Power Steering Models)
- Disconnect vacuum hose No. 24 from air control valve B and connect hand vacuum pump to valve. Disconnect air hose No. 6 from air control valve B and connect pressure gauge and hand vacuum pump. Force air into air control valve B.
- When vacuum is applied to diaphragm of air control valve B, air should flow and pressure gauge should not indicate any build-up. When vacuum is released, air should not flow and pressure gauge should indicate build-up. If valve fails either test, replace valve and retest.