2-Way Valve
- Remove fuel filler cap. Disconnect vapor hose from fuel tank side of 2-way valve, located in fuel tank area. Install "T" fitting into hose. Connect vacuum gauge and vacuum pump to "T" fitting.
- Slowly apply vacuum while observing vacuum gauge. Vacuum should stabilize momentarily at 0.2-0.6 in. Hg. If vacuum is as specified, go to next step. If vacuum is not as specified, replace 2-way valve. Retest system.