Sensor Operating Range Charts
NOTE:
Unless stated otherwise in test procedure, perform all voltage tests using a Digital Volt-Ohmmeter (DVOM) with a minimum 10-megohm input impedance.
COOLANT TEMP (ECT) SENSOR RESISTANCE TEST
| Temperature - °F (°C) |
Ohms |
| -4 (-20) |
15,000-18,000 |
| 68 (20) |
1000-4000 |
| 176 (80) |
200-400 |
INTAKE AIR TEMP (IAT) SENSOR RESISTANCE TEST
| Temperature - °F (°C) |
Ohms |
| -4 (-20) |
15,000-18,000 |
| 68 (20) |
1000-4000 |
| 176 (80) |
200-400 |
MAP SENSOR VOLTAGE TEST
| Vacuum Applied - In. Hg |
Volts |
| 0 |
2.8-3.0 |
| 5 |
2.3-2.5 |
| 10 |
1.8-2.0 |
| 15 |
1.3-1.5 |
| 20 |
.8-1.0 |
| 25 |
.3-.5 |
EGR LIFT SENSOR VOLTAGE TEST
| Position |
Volts (Approximate) |
| Fully Closed |
1.2 |
| Fully Open |
4.3 |
OXYGEN SENSOR VOLTAGE TEST
| Condition |
Volts |
| Lean |
Less Than 0.4 |
| Rich |
Greater Than 0.6 |
THROTTLE ANGLE (POSITION) SENSOR SPECIFICATIONS
| Condition |
Volts |
| Throttle Valve |
| Fully Closed |
.5 |
| Wide Open |
4.5 |
VEHICLE SPEED SENSOR (VSS) TEST
| Application |
Voltage |
| Prelude |
| Except H22A1 Engine |
5 |
| H22A1 Engine |
12 |