LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Honda >> 2003 >> S2000 >> Repair and Diagnosis >> Engine Performance >> System >> EVAP System >> Fuel Tank Vapor Control Valve Test >> Float Test
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Float Test

  1. Make sure the fuel tank is less than half full.
  2. Remove the fuel fill cap to relieve the fuel tank pressure, then reinstall the cap.
  3. Remove the fuel pipe cover. Disconnect the fuel tank vapor recirculation tube (A), and connect a commercially available vacuum pump/gauge, 0-30 in.Hg, to the hose.
    Fig 1: Disconnecting Fuel Tank VAPOR Recirculation Tube
    G03692872Courtesy of AMERICAN HONDA MOTOR CO., INC.
  4. Plug the fuel tank vapor recirculation pipe (B).
  5. Apply vacuum to the fuel tank vapor recirculation tube (A).