Float Test

  1. Make sure the fuel tank is less than half full.
  2. Remove the fuel fill cap to relieve the fuel tank pressure, then reinstall the cap.
  3. Remove the bolts and fuel tank vapor control valve cover (A).
    Fig 1: Removing The Bolts & Fuel Tank Vapor Control Cover
    G01511942Courtesy of AMERICAN HONDA MOTOR CO., INC.
  4. Remove the bolts (A).
    Fig 2: Removing The Bolts
    G01511943Courtesy of AMERICAN HONDA MOTOR CO., INC.
  5. Disconnect the fuel tank vapor recirculation tube (A), and connect a vacuum pump to the tube.
    Fig 3: Disconnecting The Fuel Tank Vapor Recirculation Tube
    G01511944Courtesy of AMERICAN HONDA MOTOR CO., INC.
  6. Plug the fuel tank vapor recirculation port (B).
  7. Apply vacuum to the fuel tank vapor recirculation tube.