Enable Conditions

  1. Stuck at Low temperature
    ENABLE CONDITIONS

    Condition Minimum Maximum
    Battery voltage 11.0 V -
    ATF temperature - -4 °F (-20 °C)
    Initial engine coolant temperature - 95 °F (35 °C)
    Engine coolant temperature 158 °F (70 °C) -
    Throttle position 4.0 ° -
    Vehicle speed 19 mph (30 km/h) -
    No active DTCs P0116, P0117, P0118, P0712, P0713, P0721, P0722
    Other After the engine coolant temperature reaches the fixed value, both the vehicle speed and the throttle position meet the conditions for at least 5 minutes
  2. Stuck at High temperature
    ENABLE CONDITIONS

    Condition Minimum Maximum
    Battery voltage 11.0 V -
    ATF temperature 230 °F (110 °C) -
    Previous engine coolant temperature when the ignition switch was turned OFF 158 °F (70 °C) -
    Present engine coolant temperature when the ignition switch is turned ON - 95 °F (35 °C)
    Engine coolant temperature 158 °F (70 °C) -
    No active DTCs P0116, P0117, P0118, P0712, P0713, P0721, P0722