ECT Sensor 1 Replacement
- Remove the air cleaner (see AIR CLEANER ELEMENT INSPECTION/REPLACEMENT
).
- Remove the EVAP canister purge valve (see EVAP CANISTER PURGE VALVE REPLACEMENT
).
- Remove the under-hood fuse/relay box bolt, and move the assembly aside.
- Drain the engine coolant (see COOLANT CHECK
).
- Disconnect the ECT sensor 1 connector (A).
Courtesy of AMERICAN HONDA MOTOR CO., INC.
- Remove ECT sensor 1 (B).
- Install the parts in the reverse order of removal with a new O-ring (C) coated with clean engine oil, then refill the radiator with engine coolant (see COOLANT CHECK
).