Without the HDS

  1. Remove the glove box (see GLOVE BOX REMOVAL/INSTALLATION ), then remove PGM-FI main relay 2 (FUEL PUMP) (A) from the under-dash fuse/relay box.

    '07-08 models 

    Fig 1: Identifying PGM-FI Main Relay 2 (FUEL PUMP)
    G05449230Courtesy of AMERICAN HONDA MOTOR CO., INC.

    '09-11 models 

    Fig 2: Identifying PGM-FI Main Relay 2
    G00487371Courtesy of AMERICAN HONDA MOTOR CO., INC.
  2. Start the engine, and let it idle until it stalls.
    NOTE: If any DTCs are stored, clear and ignore them.
  3. Turn the ignition switch to LOCK (0).
  4. Remove the fuel fill cap.
  5. Do the battery terminal disconnection procedure (see DISCONNECTION ).
  6. Remove the quick-connect fitting cover (A).
    Fig 3: Identifying Quick-Connect Fitting Cover
    G05449231Courtesy of AMERICAN HONDA MOTOR CO., INC.
  7. Check the fuel quick-connect fitting for dirt, and clean it if needed.
  8. Place a rag or shop towel over the quick-connect fitting (A).
    Fig 4: Identifying Fuel Quick-Connect Fitting For Dirt & Clean
    G05449232Courtesy of AMERICAN HONDA MOTOR CO., INC.
  9. Disconnect the quick-connect fitting (A): Hold the connector (B) with one hand, and squeeze the retainer tabs (C) with the other hand to release them from the locking tabs (D). Pull the connector off.
    NOTE:
    • Be careful not to damage the line (E) or other parts.
    • Do not use tools.
    • If the connector does not move, keep the retainer tabs pressed down, and alternately pull and push the connector until it comes off easily.
    • Do not remove the retainer from the line; once removed, the retainer must be replaced with a new one.
      Fig 5: Pulling Connector
      G05449233Courtesy of AMERICAN HONDA MOTOR CO., INC.
  10. After disconnecting the quick-connect fitting, check it for dirt or damage (see step  4 ).
  11. Do the battery terminal reconnection procedure (see RECONNECTION ).