Malfunction Threshold
A malfunction is detected if the following conditions are present after the engine has stopped and the ignition switch has been turned to LOCK (0), for at least 6 hours before restarting the engine:
| Temperature difference between each sensor values |
Malfunction judgment |
| ECT1 - ECT2 |
IAT - ECT2 |
ECT sensor 1 |
IAT sensor |
ECT sensor 2 |
| Higher than 57 °F (32 °C) |
Higher than 57 °F (32 °C) |
Normal |
Normal |
Failure |
| From -43 °F (-24 °C) to 57 °F (32 °C) |
Failure |
Normal |
Normal |
| Lower than -43 °F (-24 °C) |
Failure |
Failure |
Normal |
| From -43 °F (-24 °C) to 57 °F (32 °C) |
Higher than 57 °F (32 °C) |
Normal |
Failure |
Normal |
| From -43 °F (-24 °C) to 57 °F (32 °C) |
Normal |
Normal |
Normal |
| From -44 °F (-25 °C) to -108 °F (-60 °C) |
Normal |
Failure |
Normal |
| Suspended |
| Lower than -108 °F (-60 °C) |
Normal |
Failure |
Normal |
| Lower than -43 °F (-24 °C) |
Higher than 57 °F (32 °C) |
Failure |
Failure |
Normal |
| From -43 °F (-24 °C) to 57 °F (32 °C) |
Failure |
Normal |
Normal |
| Lower than -43 °F (-24 °C) |
Normal |
Normal |
Failure |