MIL Circuit Troubleshooting

  1. Turn the ignition switch to ON (II).
  2. Do the gauge self-diagnostic function (see SELF-DIAGNOSTIC FUNCTION ).

    Does the MIL flash? 

    YES  -Go to step 3.

    NO  -Substitute a known-good gauge control module (see GAUGE CONTROL MODULE REPLACEMENT ), then recheck. If the symptom/indication goes away with a known-good gauge control module, replace the original gauge control module (see GAUGE CONTROL MODULE REPLACEMENT ).

  3. Connect the HDS to the DLC (see GENERAL TROUBLESHOOTING INFORMATION ).
  4. Check the SCS in the DATA LIST with the HDS.

    Is a short indicated? 

    YES  -Go to step 5.

    NO  -Update the PCM if it does not have the latest software (see PCM UPDATE ), or substitute a known-good PCM (see SUBSTITUTING THE PCM ), then recheck. If the symptom/indication goes away and the PCM was updated, troubleshooting is complete. If the symptom/indication goes away and the PCM was substituted, replace the original PCM (see PCM REPLACEMENT ).

  5. Turn the ignition switch to LOCK (0).
  6. Disconnect PCM connector A (49P), then disconnect the HDS.
  7. Check for continuity between PCM connector terminal A32 and body ground.
    Fig 1: Checking Continuity Between PCM Connector Terminal A32 And Body Ground
    G08092343Courtesy of AMERICAN HONDA MOTOR CO., INC.

    Is there continuity? 

    YES  -Repair a short in the wire between the PCM (A32) and the DLC.

    NO  -Update the PCM if it does not have the latest software (see PCM UPDATE  ), or substitute a known-good PCM (see SUBSTITUTING THE PCM ), then recheck. If the symptom/indication goes away and the PCM was updated, troubleshooting is complete. If the symptom/indication goes away and the PCM was substituted, replace the original PCM (see PCM REPLACEMENT  ).