Shift Control - Shift Solenoid Valves

Shift solenoid valves use the ON-OPEN/OFF-CLOSE type; the shift solenoid valve opens the port for shift solenoid valve pressure while the shift solenoid valve is turned ON by the PCM, and closes the port when shift solenoid valve is OFF.

The combination of driving signals to shift solenoid valves A, B, C, and D are shown in the table.

GEAR POSITION AND DESCRIPTION

Position Gear Position Shift Solenoid Valve
A B C D
D, D3, and S Shifting from N OFF OFF OFF OFF
Stays in 1st OFF ON OFF OFF or ON
Shifting gears between 1st and 2nd ON ON OFF OFF or ON
Stays in 2nd ON OFF OFF OFF or ON
Shifting gears between 2nd and 3rd OFF OFF OFF OFF or ON
Stays in 3rd OFF OFF ON OFF or ON
D and S Shifting gears between 3rd and 4th ON OFF ON OFF or ON
Stays in 4th ON ON ON OFF or ON
D Shifting gears between 4th and 5th OFF ON ON OFF or ON
Stays in 5th OFF ON OFF OFF or ON
S with sequential sportshift mode 1st OFF ON OFF OFF or ON
2nd ON OFF OFF OFF or ON
3rd OFF OFF ON OFF or ON
4th ON ON ON OFF or ON
5th OFF ON OFF OFF or ON
2 2nd ON OFF OFF OFF
1 1st OFF ON OFF OFF
N Neutral OFF OFF OFF OFF
R Shifting from P and N OFF OFF ON ON
Stays in reverse OFF ON ON ON
Reverse inhibit control ON OFF ON OFF
P Park OFF OFF OFF ON