LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Honda >> 2013 >> Insight Base >> Repair and Diagnosis >> Transmission >> Automatic Trans >> CVT >> CVT Driven Pulley Pressure Control Solenoid Valve Replacement
April 5, 2026: LEMON Manuals is launched! Read the announcement.

CVT Driven Pulley Pressure Control Solenoid Valve Replacement

  1. Remove the lower valve body (see LOWER VALVE BODY REMOVAL/INSTALLATION ).
  2. Remove the inhibitor solenoid (see INHIBITOR SOLENOID REMOVAL/INSTALLATION ).
  3. Disconnect the CVT driven pulley pressure control solenoid valve 2P connector (A) and the CVTF temperature sensor (B).
    Fig 1: CVT Driven Pulley Pressure Control Solenoid Valve 2P Connector And Bolts With Torque Specifications
    G08093130Courtesy of AMERICAN HONDA MOTOR CO., INC.
  4. Remove the CVT driven pulley pressure control solenoid valve (C), the dowel pins (D), and the separator plate (E).
  5. Check that the filter (F) is in good condition, replace it if it is clogged or damaged.
  6. If the filter was removed, install the filter in the lower valve body.
  7. Install the dowel pins and the separator plate on the lower valve body.
  8. Install a new CVT driven pulley pressure control solenoid valve.
  9. Check the connector for corrosion or dirt, and clean or repair if necessary.
  10. Connect the CVT driven pulley pressure control solenoid valve 2P connector and the CVTF temperature sensor.
  11. Install the inhibitor solenoid (see INHIBITOR SOLENOID REMOVAL/INSTALLATION ).
  12. Install the lower valve body (see LOWER VALVE BODY REMOVAL/INSTALLATION ).