Enable Conditions
| Condition | Minimum | Maximum | ||||
|---|---|---|---|---|---|---|
| Battery module temperature | 131 °F (55 °C)(1) | - | ||||
| - | 3 °F (-15 °C)(2) | |||||
| MCM power-supply voltage | 10.2 V | - | ||||
| IPU module fan mode | High(1) | |||||
| Low(2) | ||||||
| Ignition switch | ON (II) | |||||
| No active DTCs set (prevents monitor from running) | P0602 (91), P0602 (92), P0A1B, P0A3F, P0A9D, P0A9E, P0AC7, P0AC8, P0ACC, P0ACD, P1448, U0029 (108), U0100 (103) | |||||
|
||||||