Enable Conditions
| Condition | Minimum | Maximum |
|---|---|---|
| Soak duration* | 6 hours | - |
| Elapsed time after the vehicle condition is turned to the ON mode | 10 second | - |
| PCM wake up engine coolant temperature [ECT Sensor 1] |
40.0 deg.F (5 deg.C) | 95 deg.F (35 deg.C) |
| Barometric pressure [Baro Sensor] |
76 kPa (22.5 inHg, 569 mmHg) | - |
| Drive distance after refueling | 7 miles (10 km) | - |
| 12 volt battery voltage [Battery] | 10.5 V | - |
| Average fuel level [Fuel Level (Average)] |
- | 85 % |
[ ]: HDS Parameter