Electric Powertrain DTCS
Motor Control Module
| DTC | Detection Item | Troubleshooting | Advanced Diagnostics | Note |
|---|---|---|---|---|
| P0562 | Traction Motor Control Module System Voltage Low | TRS | AD | |
| P0602 | Traction Motor Control Module Programming Error | TRS | AD | |
| P0602 | Generator Motor Control Module Programming Error | TRS | AD | |
| P061B | Traction Motor Control Module Torque Calculation Performance | TRS | AD | *1 |
| P062F | Traction Motor Control Module EEPROM Error | TRS | AD | |
| P062F | Generator Motor Control Module EEPROM Error | TRS | AD | |
| P0634 | PCU Internal Temperature Too High | TRS | AD | |
| P06B1 | Traction Motor Phase Current Sensor Power Supply Circuit Low (Phase U) | TRS | AD | |
| P06B1 | Generator Motor Phase Current Sensor Power Supply Circuit Low (Phase U) | TRS | AD | |
| P06B4 | Traction Motor Phase Current Sensor Power Supply Circuit Low (Phase V) | TRS | AD | |
| P06B4 | Generator Motor Phase Current Sensor Power Supply Circuit Low (Phase V) | TRS | AD | |
| P06E7 | Traction Motor Phase Current Sensor Power Supply Circuit Low (Phase W) | TRS | AD | |
| P06E7 | Generator Motor Phase Current Sensor Power Supply Circuit Low (Phase W) | TRS | AD | |
| P0710 | Transmission Fluid Temperature Sensor Circuit Range/Performance | TRS | AD | |
| P0711 | Transmission Fluid Temperature Sensor Circuit | TRS | AD | |
| P0712 | Transmission Fluid Temperature Sensor Circuit Low | TRS | AD | |
| P0713 | Transmission Fluid Temperature Sensor Circuit High | TRS | AD | |
| P0A1A | Generator Motor Control Module (Traction Motor Control Module Detected) | TRS | AD | |
| P0A1A | Generator Motor Control Module | TRS | AD | |
| P0A1B | Traction Motor Control Module | TRS | AD | |
| P0A2A | Traction Motor Temperature Sensor Circuit | TRS | AD | *1 |
| P0A2B | Traction Motor Temperature Sensor Circuit Range/Performance | TRS | AD | |
| P0A2C | Traction Motor Temperature Sensor Circuit Low | TRS | AD | |
| P0A2D | Traction Motor Temperature Sensor Circuit High | TRS | AD | |
| P0A2F | Traction Motor Over Temperature | TRS | AD | |
| P0A3C | Traction Motor Inverter Over Temperature | TRS | AD | |
| P0A3E | Generator Motor Inverter Over Temperature | TRS | AD | |
| P0A3F | Traction Motor Rotor Position Sensor Circuit | TRS | AD | |
| P0A40 | Traction Motor Rotor Position Sensor Circuit Range/Performance | TRS | AD | |
| P0A41 | Traction Motor Rotor Position Sensor Circuit Low | TRS | AD | |
| P0A4B | Generator Motor Rotor Position Sensor Circuit | TRS | AD | |
| P0A4C | Generator Motor Rotor Position Sensor Circuit Range/Performance | TRS | AD | |
| P0A4D | Generator Motor Rotor Position Sensor Circuit Low | TRS | AD | |
| P0A5E | Traction Motor Phase U Current Low | TRS | AD | |
| P0A5F | Traction Motor Phase U Current High | TRS | AD | |
| P0A61 | Traction Motor Phase V Current Low | TRS | AD | |
| P0A62 | Traction Motor Phase V Current High | TRS | AD | |
| P0A64 | Traction Motor Phase W Current Low | TRS | AD | |
| P0A65 | Traction Motor Phase W Current High | TRS | AD |
*1: This DTC code does not store individually. Details depend on other DTC codes stored at the same time.
| DTC | Detection Item | Troubleshooting | Advanced Diagnostics | Note |
|---|---|---|---|---|
| P0A70 | Generator Motor Phase U Current Low | TRS | AD | |
| P0A71 | Generator Motor Phase U Current High | TRS | AD | |
| P0A73 | Generator Motor Phase V Current Low | TRS | AD | |
| P0A74 | Generator Motor Phase V Current High | TRS | AD | |
| P0A76 | Generator Motor Phase W Current Low | TRS | AD | |
| P0A77 | Generator Motor Phase W Current High | TRS | AD | |
| P0A78 | Traction Motor Inverter Performance | TRS | AD | *1 |
| P0A7A | Generator Motor Inverter Performance (Traction Motor Control Module Detected) | TRS | AD | *1 |
| P0A7A | Generator Motor Inverter Performance | TRS | AD | *1 |
| P0A90 | Traction Motor Performance | TRS | AD | |
| P0A92 | Generator Motor Performance | TRS | AD | |
| P0AED | Traction Motor Inverter Temperature Sensor 1 Circuit | TRS | AD | |
| P0AEE | Traction Motor Inverter Temperature Sensor 1 Circuit Range/Performance | TRS | AD | |
| P0AEF | Traction Motor Inverter Temperature Sensor 1 Circuit Low | TRS | AD | |
| P0AF0 | Traction Motor Inverter Temperature Sensor 1 Circuit High | TRS | AD | |
| P0AF2 | Traction Motor Inverter Temperature Sensor 2 Circuit | TRS | AD | |
| P0AF3 | Traction Motor Inverter Temperature Sensor 2 Circuit Range/Performance | TRS | AD | |
| P0AF4 | Traction Motor Inverter Temperature Sensor 2 Circuit Low | TRS | AD | |
| P0AF5 | Traction Motor Inverter Temperature Sensor 2 Circuit High | TRS | AD | |
| P0BCC | Generator Motor Inverter Temperature Sensor Circuit | TRS | AD | |
| P0BCD | Generator Motor Inverter Temperature Sensor Circuit Range/Performance | TRS | AD | |
| P0BCE | Generator Motor Inverter Temperature Sensor Circuit Low | TRS | AD | |
| P0BCF | Generator Motor Inverter Temperature Sensor Circuit High | TRS | AD | |
| P0BE6 | Traction Motor Phase U Current Sensor Circuit Range/Performance | TRS | AD | |
| P0BEA | Traction Motor Phase V Current Sensor Circuit Range/Performance | TRS | AD | |
| P0BEE | Traction Motor Phase W Current Sensor Circuit Range/Performance | TRS | AD | |
| P0BFD | Traction Motor Phase U-V-W Current Sensor Correlation | TRS | AD | *1 |
| P0C0C | Traction Motor Inverter Power Supply Circuit Low | TRS | AD | |
| P0C39 | DC-DC Converter Temperature Sensor Range/Performance | TRS | AD | |
| P0C3A | DC-DC Converter Temperature Sensor Low | TRS | AD | |
| P0C3B | DC-DC Converter Temperature Sensor High | TRS | AD | |
| P0C4E | Traction Motor Rotor Position Exceeded Learning Limit | TRS | AD | |
| P0CE9 | PCU Electric Coolant Pump Control Circuit Open | TRS | AD | *1 |
| P0CEA | PCU Electric Coolant Pump Performance | TRS | AD | *1 |
| P0CED | PCU Electric Coolant Pump Enable Circuit | TRS | AD | |
| P0CEE | PCU Coolant Temperature Sensor Circuit | TRS | AD | |
| P0CEF | PCU Coolant Temperature Sensor Circuit Range/Performance | TRS | AD | |
| P0CF0 | PCU Coolant Temperature Sensor Circuit Low | TRS | AD | |
| P0CF1 | PCU Coolant Temperature Sensor Circuit High | TRS | AD | |
| P0D32 | DC-DC Converter Over Temperature (Traction Motor Control Module Detected) | TRS | AD | |
| P0DFA | Generator Motor Phase U-V-W Current Sensor Correlation | TRS | AD | *1 |
| P0DFB | Generator Motor Rotor Position Sensor Exceeding Learn Limit | TRS | AD | |
| P0E01 | Generator Motor Phase U Current Sensor Circuit Range/Performance | TRS | AD |
*1: This DTC code does not store individually. Details depend on other DTC codes stored at the same time.
| DTC | Detection Item | Troubleshooting | Advanced Diagnostics | Note |
|---|---|---|---|---|
| P0E05 | Generator Motor Phase V Current Sensor Circuit Range/Performance | TRS | AD | |
| P0E09 | Generator Motor Phase W Current Sensor Circuit Range/Performance | TRS | AD | |
| P0E56 | DC-DC Converter Voltage Sensor Circuit Low | TRS | AD | |
| P0E57 | DC-DC Converter Voltage Sensor Circuit High | TRS | AD | |
| P1437 | Traction Motor Inverter Short | TRS | AD | |
| P1440 | Traction Motor Inverter Gate Line Open | TRS | AD | |
| P15A5 | Traction Motor Inverter Current Too High | TRS | AD | |
| P1A54 | Traction Motor Control Module Torque Control Performance | TRS | AD | |
| P1A55 | Traction Motor Control Module Torque Adjustment Performance | TRS | AD | |
| P1A56 | Traction Motor Current Too High | TRS | AD | |
| P1A57 | Traction Motor Phase Current Sensor | TRS | AD | |
| P1A63 | VCU V2 Voltage Sensor Circuit Range/Performance | TRS | AD | |
| P1A64 | PCU Internal Failure (Communication Error) | TRS | AD | |
| P1A65 | Motor Inverter Internal Failure | TRS | AD | |
| P1A87 | VCU V0 Voltage Sensor Circuit Range/Performance (Over Voltage Range) | TRS | AD | |
| P1A88 | VCU V1 Voltage Sensor Circuit Range/Performance (Under Voltage Range) | TRS | AD | |
| P1A89 | VCU V1 Voltage Sensor Circuit Range/Performance (Over Voltage Range) | TRS | AD | |
| P1D05 | Traction Motor Control Module Internal Communication Failure | TRS | AD | |
| P1D11 | Traction Motor Phase Current Sensor Circuit Range/Performance | TRS | AD | |
| P1D13 | Generator Motor Phase Current Sensor Range/Performance | TRS | AD | |
| P1D18 | Traction Motor Temperature Sense Failure | TRS | AD | |
| P1D1B | VCU V2S Voltage Sensor Circuit High | TRS | AD | |
| P1D1C | VCU V2S Voltage Sensor Circuit | TRS | AD | |
| P1D1D | VCU V0 Voltage Sensor Circuit Low | TRS | AD | |
| P1D6E | Traction Motor Temperature Sensor Circuit Performance | TRS | AD | |
| P1D70 | Traction Motor Phase Current Sensor Multiple Performance | TRS | AD | |
| P1D72 | Traction Motor Temperature Sensor Circuit Range/Performance (Lo Side) | TRS | AD | |
| P1D77 | VCU I1 Current Sensor Circuit Range/Performance | TRS | AD | |
| P1D78 | VCU I1 Current Sensor Circuit Low | TRS | AD | |
| P1D79 | VCU I1 Current Sensor Circuit High | TRS | AD | |
| P1D7A | Reactor Temperature Sensor Circuit Range/Performance Problem | TRS | AD | |
| P1D7B | Reactor Over Temperature (Traction Motor Control Module Detected) | TRS | AD | |
| P1D7D | Reactor Temperature Sensor 1 Circuit Low | TRS | AD | |
| P1D7E | Reactor Temperature Sensor 1 Circuit High | TRS | AD | |
| P1D7F | Generator Motor Inverter Malfunction Signal Low (Generator Motor Control Module Detected) | TRS | AD | |
| P1D81 | VCU Malfunction Signal Low (Traction Motor Control Module Detected) | TRS | AD | |
| P1D85 | Traction Motor Inverter Malfunction Signal Low (Traction Motor Control Module Detected) | TRS | AD | |
| P1D8A | Generator Motor Inverter Gate Line Open | TRS | AD | |
| P1D8C | Generator Motor Inverter Over Current | TRS | AD | |
| P1D8D | Generator Motor Inverter Short | TRS | AD | |
| P1D92 | PCU Electric Coolant Pump Control Circuit | TRS | AD | |
| P1D93 | PCU Coolant Over Temperature | TRS | AD | |
| P1D97 | Generator Motor Phase Current Sensors Multiple Failure | TRS | AD |
*1: This DTC code does not store individually. Details depend on other DTC codes stored at the same time.
| DTC | Detection Item | Troubleshooting | Advanced Diagnostics | Note |
|---|---|---|---|---|
| P1D99 | PCU Electric Coolant Pump | TRS | AD | |
| P1D9A | PCU Electric Coolant Pump Circuit | TRS | AD | |
| P1D9D | VCU Temperature Sensor Circuit Range/Performance | TRS | AD | |
| P1DA0 | VCU Inverter Temperature Sensor Circuit Low | TRS | AD | |
| P1DA1 | VCU Inverter Temperature Sensor Circuit High | TRS | AD | |
| P1DA4 | VCU Inverter Short | TRS | AD | |
| P1DA6 | VCU V1 Voltage Sensor Circuit Range/Performance | TRS | AD | |
| P1DA8 | VCU V2M Voltage Sensor Circuit Range/Performance | TRS | AD | |
| P1DAA | VCU V2S Voltage Sensor Circuit Range/Performance | TRS | AD | |
| P1DD8 | VCU Inverter Temperature Sensor Circuit | TRS | AD | |
| P1DD9 | VCU I1 Current Sensor Circuit | TRS | AD | |
| P1DDB | Reactor Temperature Sensor Circuit | TRS | AD | |
| P1DE3 | VCU V1 Voltage Sensor Circuit High | TRS | AD | |
| P1DE4 | VCU V1 Voltage Sensor Circuit | TRS | AD | |
| P1DE5 | VCU V2M Voltage Sensor Circuit High | TRS | AD | |
| P1DE6 | VCU V2M Voltage Sensor Circuit | TRS | AD | |
| P1DE7 | VCU V0 Voltage Sensor Circuit High | TRS | AD | |
| P1DE8 | VCU V0 Voltage Sensor Circuit | TRS | AD | |
| P1DE9 | VCU V0 Voltage Sensor Circuit Range/Performance | TRS | AD | |
| P1DEA | VCU V0 Voltage Control Failure | TRS | AD | |
| P1F3C | VCU Over Temperature | TRS | AD | |
| P2ECB | Generator Motor Performance | TRS | AD | |
| U0029 | F-CAN Malfunction (Traction Motor Control Module Bus-Off) | TRS | AD | |
| U0038 | EP-CAN Malfunction (Traction Motor Control Module Bus-Off) | TRS | AD | |
| U0100 | CAN Malfunction (Traction Motor Control Module - PCM) | TRS | AD | *1 |
| U0111 | CAN Malfunction (Traction Motor Control Module - Battery Condition Monitor Module) | TRS | AD | *1 |
| U0146 | F-CAN Malfunction (Traction Motor Control Module - CAN Gateway) | TRS | AD | |
| U0311 | Traction Motor Control Module Programming Error (Version Mismatch) | TRS | AD | |
| U1204 | EP-CAN Malfunction (Traction Motor Control Module - PCM) | TRS | AD | |
| U1206 | EP-CAN Malfunction (Traction Motor Control Module - Battery Condition Monitor Module) | TRS | AD | |
| U1600 | F-CAN Malfunction (Traction Motor Control Module - PCM) | TRS | AD | |
| U1603 | F-CAN Malfunction (Traction Motor Control Module - Battery Condition Monitor Module) | TRS | AD |
*1: This DTC code does not store individually. Details depend on other DTC codes stored at the same time.
Battery Condition Monitor Module
| DTC | Detection Item | Troubleshooting | Advanced Diagnostics | Note |
|---|---|---|---|---|
| P0562 | Battery Condition Monitor Module System Voltage Low | TRS | AD | |
| P0602 | Battery Condition Monitor Module Programming Error | TRS | AD | |
| P062F | Battery Condition Monitor Module EEPROM Error | TRS | AD | *1 |
| P06B1 | HV Battery Current Sensor Power Supply Circuit Low | TRS | AD | |
| P0A1F | Battery Condition Monitor Module | TRS | AD | |
| P0A7E | HV Battery Pack Over Temperature | TRS | AD | |
| P0A7F | HV Battery Pack Deterioration | TRS | AD | *1 |
| P0A80 | Replace HV Battery Pack | TRS | AD | |
| P0A82 | HV Battery Pack Cooling Fan Performance/Stuck Off | TRS | AD |
*1: This DTC code does not store individually. Details depend on other DTC codes stored at the same time.
*2: '19, '20-21KX models
*3: '20-21KA and KC models
| DTC | Detection Item | Troubleshooting | Advanced Diagnostics | Note |
|---|---|---|---|---|
| P0A94 | DC-DC Converter Performance | TRS | AD | |
| P0A9B | HV Battery Temperature Sensor 1 Circuit | TRS | AD | |
| P0A9C | HV Battery Temperature Sensor 1 Circuit Range/Performance | TRS | AD | |
| P0A9D | HV Battery Temperature Sensor 1 Circuit Low | TRS | AD | |
| P0A9E | HV Battery Temperature Sensor 1 Circuit High | TRS | AD | |
| P0AA1 | HV Battery Main Contactor Circuit Stuck Closed | TRS | AD | |
| P0AA3 | HV Battery Sub Contactor Circuit | TRS | AD | |
| P0AA6 | HV Battery Voltage System Isolation Fault | TRS | AD | |
| P0AA7 | HV Battery Voltage Isolation Sensor Circuit | TRS | AD | |
| P0ABF | HV Battery Pack Current Sensor Circuit | TRS | AD | *1 |
| P0AC0 | HV Battery Pack Current Sensor Circuit Range/Performance | TRS | AD | *1 |
| P0AC1 | HV Battery Pack Current Sensor Circuit Low | TRS | AD | *1 |
| P0AC2 | HV Battery Pack Current Sensor Circuit High | TRS | AD | *1 |
| P0AC3 | HV Battery Pack Current Sensor Circuit Intermittent/Erratic | TRS | AD | *1 |
| P0AC5 | HV Battery Temperature Sensor 2 Circuit | TRS | AD | |
| P0AC6 | HV Battery Temperature Sensor 2 Circuit Range/Performance | TRS | AD | |
| P0AC7 | HV Battery Temperature Sensor 2 Circuit Low | TRS | AD | |
| P0AC8 | HV Battery Temperature Sensor 2 Circuit High | TRS | AD | |
| P0ACA | HV Battery Temperature Sensor 3 Circuit | TRS | AD | |
| P0ACB | HV Battery Temperature Sensor 3 Circuit Range/Performance | TRS | AD | |
| P0ACC | HV Battery Temperature Sensor 3 Circuit Low | TRS | AD | |
| P0ACD | HV Battery Temperature Sensor 3 Circuit High | TRS | AD | |
| P0AE1 | HV Battery Precharge Contactor Circuit | TRS | AD | |
| P0AE8 | HV Battery Temperature Sensor 4 Circuit | TRS | AD | |
| P0AE9 | HV Battery Temperature Sensor 4 Circuit Range/Performance | TRS | AD | |
| P0AEA | HV Battery Temperature Sensor 4 Circuit Low | TRS | AD | |
| P0AEB | HV Battery Temperature Sensor 4 Circuit High | TRS | AD | |
| P0AFA | HV Battery System Voltage Low | TRS | AD | |
| P0B3B | HV Battery Cell Voltage Sense Circuit 1 | TRS | AD | |
| P0B40 | HV Battery Cell Voltage Sense Circuit 2 | TRS | AD | |
| P0B45 | HV Battery Cell Voltage Sense Circuit 3 | TRS | AD | |
| P0B4A | HV Battery Cell Voltage Sense Circuit 4 | TRS | AD | |
| P0B4F | HV Battery Cell Voltage Sense Circuit 5 | TRS | AD | |
| P0B54 | HV Battery Cell Voltage Sense Circuit 6 | TRS | AD | |
| P0BC2 | HV Battery Temperature Sensor 5 Circuit | TRS | AD | |
| P0BC3 | HV Battery Temperature Sensor 5 Circuit Range/Performance | TRS | AD | |
| P0BC4 | HV Battery Temperature Sensor 5 Circuit Low | TRS | AD | |
| P0BC5 | HV Battery Temperature Sensor 5 Circuit High | TRS | AD | |
| P0D32 | DC-DC Converter Over Temperature (Battery Condition Monitor Module Detected) | TRS | AD | |
| P0DA8 | HV Battery Voltage/Motor Inverter Voltage Correlation | TRS | AD | |
| P0DE6 | HV Battery Pack Voltage Low | TRS | AD | |
| P0DE7 | HV Battery Pack Voltage High | TRS | AD | |
| P0E2D | HV Battery Cell Voltage Sense Circuit | TRS | AD | |
| P1447 | HV Battery Pack Deterioration (Middle Severity) | TRS | AD | |
| P144A | HV Battery Pack Deterioration (High Severity) | TRS | AD | |
| P1586 | HV Battery Current Sensor | TRS | AD |
*1: This DTC code does not store individually. Details depend on other DTC codes stored at the same time.
*2: '19, '20-21 KX models
*3: '20-21 KA and KC models
| DTC | Detection Item | Troubleshooting | Advanced Diagnostics | Note |
|---|---|---|---|---|
| P158A | HV Battery Current Sensor Correlation | TRS | AD | |
| P158B | HV Battery Current Sensor 1 Circuit | TRS | AD | |
| P158D | HV Battery Current Sensor 1 Circuit Low | TRS | AD | |
| P158E | HV Battery Current Sensor 2 Circuit Low | TRS | AD | |
| P158F | HV Battery Current Sensor 1 Circuit High | TRS | AD | |
| P1596 | HV Battery Current Sensor 2 Circuit High | TRS | AD | |
| P1597 | HV Battery Current Sensor 1 Circuit Range/Performance | TRS | AD | |
| P1598 | HV Battery Current Sensor 2 Circuit Range/Performance | TRS | AD | |
| P1673 | IGHLD Relay Circuit | TRS | AD | |
| P16C3 | DC-DC Converter Temperature Sensor Circuit | TRS | AD | |
| P1D3A | Battery Condition Monitor Module EEPROM Error (FSA Operated) | TRS | AD | |
| P1D3B | Battery Condition Monitor Module EEPROM Error (FSA Not-Operated) | TRS | AD | |
| P1D64 | Collision Detection Signal Circuit | TRS | AD | |
| P1D65 | HV System Shutdown (Collision Detection Signal Detected) | TRS | AD | |
| P1DC7 | HV Battery Pack Deterioration of Power | TRS | AD | |
| P1DCB | HV Battery Identification Circuit (System Running) | TRS | AD | |
| P1DFD | Power System Indicator Lighting Request From PCM | TRS | AD | |
| P1DFF | IGHLDB Relay Circuit | TRS | AD | |
| P262B | Battery Condition Monitor Module Timer | TRS | AD | |
| U0029 | F-CAN Malfunction (Battery Condition Monitor Module Bus-Off) | TRS | AD | |
| U0038 | EP-CAN Malfunction (Battery Condition Monitor Module Bus-Off) | TRS | AD | |
| U0100 | CAN Malfunction (Battery Condition Monitor Module - PCM) | TRS | AD | *1 |
| U0110 *2 | F-CAN Malfunction (Battery Condition Monitor Module - Traction Motor Control Module) | TRS | AD | |
| U0110 *3 | F-CAN Malfunction (Battery Condition Monitor Module - Traction Motor Control Module) | TRS | AD | *1 |
| U012D *2 | F-CAN Malfunction (Battery Condition Monitor Module - Generator Motor Control Module) | TRS | AD | |
| U012D *3 | F-CAN Malfunction (Battery Condition Monitor Module - Generator Motor Control Module) | TRS | AD | *1 |
| U0146 | F-CAN Malfunction (Battery Condition Monitor Module - CAN Gateway) | TRS | AD | |
| U0155 | F-CAN Malfunction (Battery Condition Monitor Module - Gauge Control Module) | TRS | AD | |
| U0298 | DC-DC Converter Communication Error | TRS | AD | *1 |
| U0312 | Battery Condition Monitor Module Programming Error (Version Mismatch) | TRS | AD | |
| U0599 | DC-DC Converter Serial Communication Receive Error | TRS | AD | |
| U1204 | EP-CAN Malfunction (Battery Condition Monitor Module - PCM) | TRS | AD | |
| U1205 | EP-CAN Malfunction (Battery Condition Monitor Module - Traction Motor Control Module) | TRS | AD | |
| U1207 | F-CAN Malfunction (Battery Condition Monitor Module - Electric A/C Compressor) | TRS | AD | |
| U1220 | DC-DC Converter Serial Communication Transmit Error | TRS | AD | |
| U12A5 | EP-CAN Malfunction (Battery Condition Monitor Module - Generator Motor Control Module) | TRS | AD | |
| U1600 | F-CAN Malfunction (Battery Condition Monitor Module - PCM) | TRS | AD | |
| U1604 | F-CAN Malfunction (Battery Condition Monitor Module - Traction Motor Control Module) | TRS | AD | |
| U1605 | F-CAN Malfunction (Battery Condition Monitor Module - Generator Motor Control Module) | TRS | AD |
*1: This DTC code does not store individually. Details depend on other DTC codes stored at the same time.
*2: '19, '20-21KX models
*3: '20-21KA and KC models