Enable Conditions
| Condition | Minimum | Maximum |
|---|---|---|
| Engine coolant temperature [ECT Sensor 1] before EVAP purge control starts | 113 deg.F (45 deg.C) | - |
| MAP value [MAP Sensor (Hi Res)] |
- | -9.0 kPa (-2.7 inHg, -70 mmHg) |
| 12 volt battery voltage [Battery] |
10.5 V | - |
| Fuel trim | 0.69 | 1.47 |
| EVAP canister purge valve duty | 20 % | 80 % |
| Fuel feedback | Closed loop at stoichiometric | |
[ ]: HDS Parameter