Possible Cause
NOTE:
The causes shown may not be a complete list of all potential problems, and it is possible that there may be other causes.
- Electric VTC motor EVTP line open
- Electric VTC motor EVTM line open
- Electric VTC motor GND line open
- Electric VTC motor EVTP line short
- Electric VTC motor EVTM line short
- Electric VTC motor GND line short
- Electric VTC motor VB1(EVTC) line short to ground
- Electric VTC motor VB2(EVTC) line short to ground
- Electric VTC motor VB2(EVTC) line open
- Electric VTC relay circuit EVTC RLY CL- line open
- Electric VTC relay circuit EVTC RLY CL- line short to power
- Electric VTC relay circuit stuck off