Service Programming System (SPS) (Off Board Remote) Procedure
For additional SPS information, refer to Service Programming System (SPS) Description .
IMPORTANT:
Ensure the Tech 2(tm) and the terminal are both equipped with the latest software before performing SPS.
- Obtain the vehicle identification number (VIN) of the vehicle for which the module is being programmed.
- Launch the TIS application at the terminal.
- Select the Service Programming System.
- Highlight the following information on the Select Diagnostic Tool and Programming Process screen:
- Select Diagnostic Tool-Select Tech 2(tm)
- Select Programming Process-Identify whether an existing module is being reprogrammed or replaced with a new one.
- Select ECU location-select Off-Board Programming Adapter.
- Select Next.
- Follow the directions on the Preparing for Communication screen for connecting the following components:
- The control module
- The Off-Board Programming Adapter (OBPA)-Refer to the TIS Users Guide for a listing of the OBPA.
- The Tech 2(tm)
- Select the Service Programming Request Information function on the Tech 2(tm).
- Follow the Tech 2(tm) instructions to obtain the module data and security information.
- After the Tech 2(tm) has received the data from the module, exit the Request Info mode.
- Disconnect the Tech 2(tm) from the OBPA.
- Turn OFF the Tech 2(tm).
- Connect the Tech 2(tm) to the terminal.
- Turn ON the Tech 2(tm).
- Select Next at the terminal after the Tech 2(tm) start-up screen appears.
- Enter the VIN of the vehicle that will be receiving the control module.
- Select Next.
- Select the type of programming to be performed from the following categories:
- Normal-Used for updating an existing calibration or programming a new controller.
- Vehicle configuration index (VCI)-Used for updating an existing controller or programming a new controller for newer vehicles whose VINs are not yet in the database.
- Reconfigure-Used to reconfigure a vehicle for changes in tire size and axle ratios.
- Select Next.
- Select a calibration on the Calibration Selection screen, if necessary.
- Ensure all the desired folder tabs have a green check mark.
- Select Next.
- Verify the current and the selected calibration of the control module on the Summary screen.
- Select Next.
- Select OK.
- On model year 1996 and newer controllers, a crankshaft position (CKP) relearn procedure box may appear. Select OK.
- Follow the on-screen instructions, if any, when the Program Controller/Programming Complete screen appears.
- Select Close.
- Turn OFF the Tech 2(tm).
- Disconnect the Tech 2(tm) from the terminal.
- Connect the Tech 2(tm) to the OBPA.
- Turn ON the Tech 2(tm).
- Select Enter at the title screen.
- Select the Service Programming System at the Main Menu.
- Select the Program ECU function.
- Select Continue.
- Follow the on-screen instructions.
- Select Continue.
- Select Exit when the programming is complete.
- Turn OFF the OBPA.
- Turn OFF the Tech 2(tm).
- Disconnect the OBPA from the Tech 2(tm) and the control module.
IMPORTANT:
The TIS supports service programming with the Tech 2(tm) scan tool only.
IMPORTANT:
Ensure the correct connector for the control module is used.
IMPORTANT:
When selecting the vehicle configuration index (VCI) programming type, a valid VCI number for the vehicle must be entered. This number may be obtained from Techline Customer Support.
IMPORTANT:
Select Cancel if you receive a message stating that the calibration selected is already the current calibration in the control module and reprogramming with the same download is not allowed.
IMPORTANT:
Wait 30 seconds after the OBPA is turned OFF before disconnecting the control module.