Installation Procedure

    Fig 1: Oiling Male Pipe Ends (Metal Collar)
    GM12784Courtesy of GENERAL MOTORS CORP.
    WARNING: In order to reduce the risk of fire and personal injury, before connecting fuel pipe fittings, always apply a few drops of clean engine oil to the male pipe ends.
    This will ensure proper reconnection and prevent a possible fuel leak.
    During normal operation, the O-rings located in the female connector will swell and may prevent proper reconnection if not lubricated.
  1. Apply a few drops of clean engine oil to the male pipe end.
  2. Fig 2: View Of Connectors (Metal Collar)
    GM12786Courtesy of GENERAL MOTORS CORP.
  3. Push both sides of the quick-connect fitting together in order to snap the retaining tabs into place.
  4. Fig 3: Ensuring Connection (Metal Collar) Is Secure
    GM12787Courtesy of GENERAL MOTORS CORP.
  5. Pull on both sides of the quick-connect fitting to make sure the connection is secure.
  6. Fig 4: View Of Quick-Connect Fitting Retainer (Metal Collar)
    GM730809Courtesy of GENERAL MOTORS CORP.
  7. Install the retainer to the quick-connect fitting.
  8. Inspect for leaks using the following procedure:
    1. Turn the ignition ON, with the engine OFF for 2 seconds.
    2. Turn the ignition OFF, for 10 seconds.
    3. Turn the ignition ON, with the engine OFF for 2 seconds.
    4. Turn the ignition OFF.
    5. Inspect for leaks.